Clinical Diagnostic Reagents Horiba Diluent Lyse Clean MICROS 45 ABX Reagents

Basic Information
Place of Origin: China
Brand Name: Dewei
Certification: ISO, CE, CFDA
Model Number: DWX-30610
Minimum Order Quantity: 500 units
Price: Negotiable
Packaging Details: 20L,1L,500ml
Delivery Time: in 20 days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 20,000L/day
Detail Information
Sample: Blood Model: ABX Micros 45
Usage: Medical Storage: Room Temperature
Expiry: 24 Months Origin: China
High Light:

abx micros 60 reagents

,

abx chemicals


Product Description

Clinical Diagnostic Reagents Horiba Diluent Lyse Clean MICROS 45 ABX Reagents

 

Specification of Horiba Reagent

ABX MICROS 45 MICROS 60
Cat. No Description Pack Size
DWX-30610 DILUENT-M 20L
DWX-30611 LYSE-M 1L
DWX-30612 RINSE-M 1L
DWX-30613 CLEAN-M 500ml

 

Intended Use of Horiba Reagent
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on ABX ( Horiba ) MICROS 45 Hematology Analyzers.

LoD of Horiba Reagent

If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details.

Storage

The product should be stored in 2℃-35℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.

 

What is a hematology reagent with barcode?

Currently,three part models needn’t scan the barcode in common, and it can be used directly with connecting the reagent bottle.

There are some models that have to scan barcode to identify new reagents, like Beckman Coulter AcT diff, Mindray 5 part models and so on.

Currently, the manufacturers of instrument are aware of the importance of consumables, so the long-term trend is to make a closed reagent system by scanning barcode to change new reagents. However,the end customers will not willing to be completely close considering of cost and benefit so there are closed system and open system in the market.

Closed system: The manufacturers impose restrictions on software by scanning their barcode when changing reagents to prevent other compatible reagents.

Open system: The manufacturers do not impose restrictions on software so that reagents can be used no matter what brands.

Clinical Diagnostic Reagents Horiba Diluent Lyse Clean MICROS 45 ABX Reagents 0Clinical Diagnostic Reagents Horiba Diluent Lyse Clean MICROS 45 ABX Reagents 1

 