Place of Origin: | China |
---|---|
Brand Name: | Dewei |
Certification: | ISO, CE, FDA, CFDA |
Model Number: | DWX-51201 |
Minimum Order Quantity: | 500 units |
Price: | Negotiable |
Packaging Details: | 20L, 5L, 500ml, 1L, 50ml, 42ml |
Delivery Time: | in 20 days |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 20,000L/day |
Model: | Maccura JASDAQ DH-510 | Shelf-life: | 24 Months |
---|---|---|---|
Sample: | Blood | Recycling: | Disposable |
Usage: | Medical Use | Differential: | 5 Part |
Highlight: | human biochemistry reagents,chemically pure reagents |
Cell Counter Chemically Reagents For Maccura JASDAQ DH-510 DH-520 DH-560 Hematology Analyzer with ISO/CE/CFDA approvel
Intended Use of Maccura reagentsTo be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on JASDAQ DH-510 DH-520 DH-560 Hematology Analyzers.
Specification of Maccura reagents
Reagents on Maccura JASDAQ DH-510 DH-520 DH-560 Analyzer | ||
Cat. No | Description | Pack Size |
DWX-51201 | DILUENT-JAS | 20L |
DWX-51202 | LYSE-5DIFF | 1L |
DWX-51203 | LYSE-5DIFF | 5L |
DWX-51204 | LYSE-HGB | 500ml |
DWX-51205 | DYE-DD5 | 42ml |
DWX-51206 | RINSE-JAS | 50ml |
1. PRECAUTIONS
Re-calibration is recommended when changing the origin of the reagents.
It is not recommended using different brands of solutions together on one unit of analyzer.
Do not ingest. Avoid contact with skin and eyes.
Skin contact: Flush with plenty of water.
Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
This kit is for professionals and in vitro diagnostic use only.
Never put distilled water on the analyzer (except clean for shipping menu), otherwise the pneumatic unit can be damaged seriously.
2. STORAGE
Store the product at 2-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
The open vial life of the product is 60 days. Unused reagents should be discarded after 60 days. Do not mix residual with a new carton.
3. Is there great difference of types between different kinds of hematology reagents?
Different analayzers have different using principles, therefore there is a great difference of types and quantities. In general, the types and quantities of reagents for use of five part hematollogy analayzers will more than three part machine.
Some product questions you may want to ask:
1) What are the reagents of hematology Analyser?
At present, hematology analyzers on the market can be divided into 3 part hematology analyzers and 5 part hematology analyzers. Hematology reagents are also indispensable in the use of hematology analyzer. Hematology reagents include hemolytic agents, diluents, cleaning solutions and concentrated cleaning solutions.
2) What is the diluent in the hematology analyzer?
The diluent for the hematology analyzer comprises sodium chloride, sodium sulfate, a phosphate buffer agent, ethylene diamine tetraacetic acid, 1-pyridone-2-sulphur and formaldehyde, and the pH value of the solution is 6.5-7.4, and preferably is 7.2; the content of each component is preferably as follows: 5g/L of ...
3) Which diluent is good for RBC and platelet counting?
For this, the blood specimen is diluted (usually in 1:200 ratio) with the help of RBC diluting fluid (commonly the Hayem's Fluid) which preserve and fix the Red blood cells. The Hayem's fluid is isotonic to the Red blood cells and does not cause any damage to it.
4) What is the use of Lyse in hematology analyzer?
It is used to lyse (destroy) red blood celis for hemogiobin determinations or aid in the counting of white blood cells. Applicable to the hematology analyzers.
5) What is the composition of Lyse for hematology analyzer?
The lytic reagent composition comprises a short chain alkyl oxyethanol selected from the group consisting of 2-methoxyethanol, 2-ethoxyethanol, 2-propoxyethanol, and 2-isopropoxyethanol in a sufficient amount to preserve leukocytes; a non-lysing nonionic surfactant as a debris solublizer; and an inorganic buffer to ...
6) Which of the following combination of reagents is used to measure hemoglobin?
This is done by adding both potassium cyanide and ferricyanide whose absorbance is then measured at 540 nm using a photoelectric colorimeter against a standard quality control solution. The Hb concentration is then determined by the result produced by the photoelectric colorimeter.
7) What is the principle of 3 part hematology analyzer?
In a 3-part analyzer the cell counting is based on the Coulter Principle. All hematology analyzers utilise Coulter's Principle. 3-part differential cell counter employs Coulter's Principle to determine the size as well as volume of the cells. Coulter's principle is applied employing two electrodes.
8) What is a particle cell counterand analyzer reagent?
A variety of reagents that are designed for some cell counters and analyzer that optimize instrument setup, sample preparation and quality control.