Send Message
products

XN Series Chemistry Analyzer Reagents Laboratory Sysmex Hematology With Closed System Barcode Chip

Basic Information
Place of Origin: China
Brand Name: Dewei
Certification: ISO, CE, FDA
Model Number: DWX-50101
Minimum Order Quantity: 500 units
Price: Negotiable
Packaging Details: 20L,4L,82ml,42ml,1.5L,12ml
Delivery Time: in 20 days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 20000L/day
Detail Information
Storage: Room Temperature Code: With Barcode Chip
Expiry: 24 Months Model: Compatible Use On Sysmex XN Series
System: Closed System Specimen: Blood Sample
High Light:

sysmex hematology analyzer reagents

,

medical lab reagents


Product Description

Compatible Use Sysmex Hematology Reaegnts XN Series XN-1000 B1 B2 B3 B4 CBC Analyzer ( with Barcode Chip )

Intended Use of XN reagentsTo be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Sysmex XN Series XN-1000 A1 A2 B1 B2 B3 B4, barcode and chips are offered with closed system.

 
Specification of XN reagents

Compatible Use on XN-1000 Series A1 A2 B1 B2 B3 B4
( with Barcode , Tape chip )

Cat. NoDescriptionPack Size
DWX-50101DILUENT-DCL20L
DWX-50102LYSE-WNR4L*2
DWX-50103DYEWNR82ml*2
DWX-50104LYSE-WDF4L*2
DWX-50105DYEWDF42ml*2
DWX-50106LYSE-SLS1.5L*2
DWX-50107DILUENT-DFL1.5L*2
DWX-50108DYERET12ml*2
DWX-50109AUTOCLEAN-SYS4ml*20
DWX-50110LYSE-WPC1.5L*2
DWX-50111DYEWPC12ml*2
DWX-50112DYEPLT12ml*2


Can CBC reagents be used in different model?
The reagents of different brands can not be used in general, and some reagents of same brands can be applied in different models. Such as ST-Diluent and ST-Clean of SYSMEX; Diluent-CD3200 of Ruby and CD3200 of ABBOTT etc. The same reagent for product code can be used for general purpose, please refer to our product brochure.
 
Should blood cell counter do a calibration before using our reagents?
First of all,if your instrument used the original reagents before using our products, you needn’t to do calibrate.
If your instrument used other compatible reagents, calibration is necessary before using our reagents.
 
Limitations of Detection Method
If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details.
Storage
The product should be stored in 2℃-35℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.
 
Attention
1. This product is an in vitro diagnostic reagent;
2. Pay attention to seal and prevent pollution;
3. Read the instructions carefully before use, and should stop using them when they exceed the period of validity;
4. If the product freezes, it should be completely defrosted at room temperature and used after mixing.
5. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations;
6. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin,please clean immediately with plenty of water and seek medical advice.
 
What are our advantages?
1. Experienced R&D with high investment.
2. Strict quality control with international standards.
3. Automated Production line, no defected product is allowed.
4. 24 hour service.
 
Limitations of Detection Method:
If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details.
 
Storage of CBC reagents
The product should be stored in 2℃-38℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.

XN Series Chemistry Analyzer Reagents Laboratory Sysmex Hematology With Closed System Barcode Chip 0XN Series Chemistry Analyzer Reagents Laboratory Sysmex Hematology With Closed System Barcode Chip 1

Contact Details
Sherry

Phone Number : +8613316305166

WhatsApp : +8615267039708