Type: | Diluent Lyse Dye | Model: | Nihon Kohden MEK-6400 |
---|---|---|---|
Sample: | Blood | Recycling: | Disposable |
Usage: | Medical,Clinical Experiments | Temperature: | 2-35 Centigrade |
Highlight: | chemistry analyzer reagents,human biochemistry reagents |
Stable Hematology Reagent / Blood Test Reagents For Nihon Kohden 5Part MEK-8222/7222
Intended Use of Nihon Kohden reagents
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Nihon Kohden MEK-6400 Hematology Analyzers.
Reagents on Nihon Kohden MEK-68222 MEK-7222 Analyzer | ||
Cat. No | Description | Pack Size |
DWX-50701 | DILUENT-NK5 | 20L |
DWX-50702 | LYSE-NK910 | 500ml X 3 |
DWX-50703 | LYSE-NK680 | 500ml X 3 |
DWX-50704 | RINSE520-NK | 5L |
DWX-50705 | RINSE520-NK | 5L |
This product is for In Vitro Diagnostic Use only.
Are the specifications of a set of reagents fixed?
Certainly, our products is produced according to the specifications od the original reagents, however, some products can be adjusted according to the demand of different customers.
PRECAUTIONS
Re-calibration is recommended when changing the origin of the reagents.
It is not recommended using different brands of solutions together on one unit of analyzer.
Do not ingest. Avoid contact with skin and eyes.
Skin contact: Flush with plenty of water.
Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
This kit is for professionals and in vitro diagnostic use only.
Never put distilled water on the analyzer (except clean for shipping menu), otherwise the pneumatic unit can be damaged seriously.
STORAGE
Store the product at 2-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
The open vial life of the product is 60 days. Unused reagents should be discarded after 60 days. Do not mix residual with a new carton.
Some product questions you may want to ask:
1) What are the reagents of hematology Analyser?
At present, hematology analyzers on the market can be divided into 3 part hematology analyzers and 5 part hematology analyzers. Hematology reagents are also indispensable in the use of hematology analyzer. Hematology reagents include hemolytic agents, diluents, cleaning solutions and concentrated cleaning solutions.
2) What is the diluent in the hematology analyzer?
The diluent for the hematology analyzer comprises sodium chloride, sodium sulfate, a phosphate buffer agent, ethylene diamine tetraacetic acid, 1-pyridone-2-sulphur and formaldehyde, and the pH value of the solution is 6.5-7.4, and preferably is 7.2; the content of each component is preferably as follows: 5g/L of ...
3) What is the use of Lyse in hematology analyzer?
It is used to lyse (destroy) red blood celis for hemogiobin determinations or aid in the counting of white blood cells. Applicable to the hematology analyzers.
4) Which of the following combination of reagents is used to measure hemoglobin?
This is done by adding both potassium cyanide and ferricyanide whose absorbance is then measured at 540 nm using a photoelectric colorimeter against a standard quality control solution. The Hb concentration is then determined by the result produced by the photoelectric colorimeter.
5) What is the principle of 3 part hematology analyzer?
In a 3-part analyzer the cell counting is based on the Coulter Principle. All hematology analyzers utilise Coulter's Principle. 3-part differential cell counter employs Coulter's Principle to determine the size as well as volume of the cells. Coulter's principle is applied employing two electrodes.
6) Will the quality of CBC reagents change with different temperature?
Normal weather change will not affect the use of the product. If the reagents freeze for low temperature, returning it to room temperature make the ice melt completely and the products can be used normally. Ensurind the ice melt completely otherwise it may cause blockage. The store temperature of hematology reagents is 2-35 degrees, and the biochemical reagents require 2-8 degrees, if not the validity of products will shorten.