Model: | RAYTO RT-7300 RT-7200 | Orgin: | Guangdong,China |
---|---|---|---|
Usage: | Medical,Clinical | Storage: | Room Temperature |
System: | Open System | Certificate: | ISO CE CFDA |
Expiry: | 24 Months | ||
High Light: | chemistry analyzer reagents,human biochemistry reagents |
High Performance Hematology Analyzer Reagent for RAYTO RT-7300 Diluent Lyse Rinse 3 Part Cell Counter
Intended Use of CBC reagents
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Rayto RT-7300 RT-7200 Hematology Analyzers.
Specification of CBC reagents
Reagents on Rayto RT-7600 RT-7300 RT-7200 CBC Analyzer | ||
Cat. No | Description | Pack Size |
DWX-31006 | DILUENT-RT3 | 20L |
DWX-31007 | LYSE-RT3 | 1L |
DWX-31008 | RINSE-RT | 5L |
Limitations of Detection Method
If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details.
Storage
The product should be stored in 2℃-35℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.
Attention
1. This product is an in vitro diagnostic reagent;
2. Pay attention to seal and prevent pollution;
3. Read the instructions carefully before use, and should stop using them when they exceed the period of validity;
4. If the product freezes, it should be completely defrosted at room temperature and used after mixing.
5. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations;
6. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin,please clean immediately with plenty of water and seek medical advice.
What is hematology reagent with barcode?
Currently, the manufacturers of instrument are aware of the importance of consumables, so the long-term trend is to make a closed reagent system by scanning barcode to change new reagents. However,the end customers will not willing to be completely close considering of cost and benefit so there are closed system and open system in the market.
Closed system: The manufacturers impose restrictions on software by scanning their barcode when changing reagents to prevent other compatible reagents.
Open system: The manufacturers do not impose restrictions on software so that reagents can be used no matter what brands.