Place of Origin: | China |
---|---|
Brand Name: | Dewei |
Certification: | ISO,CE,CFDA,FDA |
Model Number: | DWX-50131 |
Minimum Order Quantity: | 500 units |
Price: | Negotiable |
Packaging Details: | 20L,5L,50ml,500ml,42ml |
Delivery Time: | in 20 days |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 20,000L/day |
Expiry: | 24 Months | Temperature: | Room Temperature |
---|---|---|---|
Code: | With Barcode, Tape Chip | Recycling: | Disponsable |
System: | Closed And Open | Country Of Origin: | China |
High Light: | sysmex hematology analyzer reagents,medical lab reagents |
High Performance Laboratory Reagents And Sysmex Hematology Reagents on XS-800i Barcode
Intended Use of CBC Reagents
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Sysmex XS-1000i XS-800i XS-500i Hematology Analyzers.
Specification of CBC Reagents
Reagents on Sysmex XS-1000i XS-800i XS-500i Analzyers | ||
Cat. No | Description | Pack Size |
DWX-50131 | DILUENT-EPK | 20L |
DWX-50132 | LYSE-SLS | 500ml×3 |
DWX-50133 | LYSE-SLS | 5L |
DWX-50134 | LYSE-4DL | 5L |
DWX-50135 | DYE-4DS(FFS) | 42ml×3 |
DWX-50136 | CLEAN-SYS | 50ml |
Attention
1. This product is an in vitro diagnostic reagent;
2. Pay attention to seal and prevent pollution;
3. Read the instructions carefully before use, and should stop using them when they exceed the period of validity;
4. If the product freezes, it should be completely defrosted at room temperature and used after mixing.
5. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations;
6. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin,please clean immediately with plenty of water and seek medical advice.
What is the function of hemolytic reagent?
It can wrap the sample blood and allow the cells to be arranged in a single line from the middle of the flow chamber, avoiding the occurrence of two cells at the same time, and then ensuring the accuracy of the cell count.
Limitations of Detection Method
If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details.
Storage
The product should be stored in 2℃-35℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.