XS-1000i Diluent Lyse Sysmex Hematology Reagents Blood Sample Room Temperature
Intended Use of Sysmex CBC Reagents
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Sysmex XS-1000i XS-800i XS-500i Hematology Analyzers, for in vitro diagnostic used.
Specification of Sysmex CBC Reagents
Reagents compatible on Sysmex XS-1000i XS-800i XS-500i Analyzers | ||
Cat. No | Description | Pack Size |
DWX-50131 | DILUENT-EPK | 20L |
DWX-50132 | LYSE-SLS | 500ml×3 |
DWX-50133 | LYSE-SLS | 5L |
DWX-50134 | LYSE-4DL | 5L |
DWX-50135 | DYE-4DS(FFS) | 42ml×3 |
DWX-50136 | CLEAN-SYS | 50ml |
Attention
1. This product is an in vitro diagnostic reagent;
2. Pay attention to seal and prevent pollution;
3. Read the instructions carefully before use, and should stop using them when they exceed the period of validity;
4. If the product freezes, it should be completely defrosted at room temperature and used after mixing.
5. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations;
6. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin,please clean immediately with plenty of water and seek medical advice.
1) Can diluent replace by rinse or cleaner?
Different reagents have different ingredients, so it is not recommended to replace the washing solutions with diluent.
2) What is the function of hemolytic reagent?
It can wrap the sample blood and allow the cells to be arranged in a single line from the middle of the flow chamber, avoiding the occurrence of two cells at the same time, and then ensuring the accuracy of the cell count.
3) Which diluent is good for RBC and platelet counting?
For this, the blood specimen is diluted (usually in 1:200 ratio) with the help of RBC diluting fluid (commonly the Hayem's Fluid) which preserve and fix the Red blood cells. The Hayem's fluid is isotonic to the Red blood cells and does not cause any damage to it.
4) What is the use of Lyse in hematology analyzer?
It is used to lyse (destroy) red blood celis for hemogiobin determinations or aid in the counting of white blood cells. Applicable to the hematology analyzers.
5) What are the reagents of hematology Analyser?
At present, hematology analyzers on the market can be divided into 3 part hematology analyzers and 5 part hematology analyzers. Hematology reagents are also indispensable in the use of hematology analyzer. Hematology reagents include hemolytic agents, diluents, cleaning solutions and concentrated cleaning solutions.
6) Which of the following combination of reagents is used to measure hemoglobin?
This is done by adding both potassium cyanide and ferricyanide whose absorbance is then measured at 540 nm using a photoelectric colorimeter against a standard quality control solution. The Hb concentration is then determined by the result produced by the photoelectric colorimeter.
7) Will the quality of CBC reagents change with different temperature?
Normal weather change will not affect the use of the product. If the reagents freeze for low temperature, returning it to room temperature make the ice melt completely and the products can be used normally. Ensurind the ice melt completely otherwise it may cause blockage. The store temperature of hematology reagents is 2-35 degrees, and the biochemical reagents require 2-8 degrees, if not the validity of products will shorten.
8) Does the instrument need to recalibrate and control when using our reagents to replace original one?
Do not need to do calibration again, and do quality control as before.