Send Message
products

XT-2100i XT-1800i Sysmex Hematology Reagents Compatible On 5 Part CBC Analyzer

Basic Information
Place of Origin: China
Brand Name: Dewei
Certification: ISO,CE,CFDA
Model Number: DWX-50123
Minimum Order Quantity: 500 units
Price: Negotiable
Packaging Details: 20L,5L,1L+12ml,500ml,42ml
Delivery Time: in 20 days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 20,000L/day
Detail Information
Type: Diluent Lyse Clean Dye Model: SYSMEX XT-2000i XT-1800i
Expiry: 24 Months Usage: Medical,Clinical Experiments
Orgin: China Specimen: Blood
Highlight:

sysmex hematology analyzer reagents

,

medical lab reagents


Product Description

XT-2100i XT-1800i Sysmex Hematology Reagents Compatible On 5 Part CBC Analyzer

 

Use of Sysmex Cell Counter Reagents?

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Sysmex XT-2100i XT-4000 XT-2000i XT-1800i Hematology Analyzers.

 

Specification of Sysmex Cell Counter Reagents?

Compatible CBC Reagents on Sysmex XT-2100i XT-4000 XT-2000i XT-1800i
Cat. No Description Pack Size
DWX-50123 DILUENT-EPK 20L
DWX-50124 LYSE-SLS 500ml×3
DWX-50125 LYSE-SLS 5L
DWX-50126 LYSE-4DL 5L
DWX-50127 LYSE-FBA 5L
DWX-50128 DYE-4DS(FFS) 42ml×3
DWX-50129 RET-PACK DILUENT-RED+DYERED 1L+12ml
DWX-50130 CLEAN-SYS 50ml

 

Reagents are for in vitro diagnostic used only.

 

Some product questions you may want to ask:

1) Should the instrument do a calibration before using our reagents?

First of all,if your instrument used the original reagents before using our products, you needn’t to do calibrate.

If your instrument used other compatible reagents, calibration is necessary before using our reagents.

 

2) Attention of Cell Counter Reagents?

1. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations;

2. Pay attention to seal and prevent pollution;

3. Read the instructions carefully before use, and should stop using them when they exceed the period of validity;

4. If the product freezes, it should be completely defrosted at room temperature and used after mixing.

5. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin,please clean immediately with plenty of water and seek medical advice.

 

3) Delivery of Cell Counter Reagents?

If it is big quantity orders of reagents, we would help to arrange sea shipment, better by full container to save the delivery cost.

If it is small order but urgent use, we would book air shipment or send it by FedEx, delivery is fast but much expensive then by sea.

 

4) Storage of Cell Counter Reagents?

The product should be stored in 2℃-35℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.

 

5) What are the reagents of hematology Analyser?
At present, hematology analyzers on the market can be divided into 3 part hematology analyzers and 5 part hematology analyzers. Hematology reagents are also indispensable in the use of hematology analyzer. Hematology reagents include hemolytic agents, diluents, cleaning solutions and concentrated cleaning solutions.

 

6) Which of the following combination of reagents is used to measure hemoglobin?
This is done by adding both potassium cyanide and ferricyanide whose absorbance is then measured at 540 nm using a photoelectric colorimeter against a standard quality control solution. The Hb concentration is then determined by the result produced by the photoelectric colorimeter.

 

7) Will the quality of CBC reagents change with different temperature?

Normal weather change will not affect the use of the product. If the reagents freeze for low temperature, returning it to room temperature make the ice melt completely and the products can be used normally. Ensurind the ice melt completely otherwise it may cause blockage. The store temperature of hematology reagents is 2-35 degrees, and the biochemical reagents require 2-8 degrees, if not the validity of products will shorten.

 

8) Does the instrument need to recalibrate and control when using our reagents to replace original one?

Do not need to do calibration again, and do quality control as before.

XT-2100i XT-1800i Sysmex Hematology Reagents Compatible On 5 Part CBC Analyzer 0XT-2100i XT-1800i Sysmex Hematology Reagents Compatible On 5 Part CBC Analyzer 1

 

 

 

Contact Details
Sherry Cai

Phone Number : 0086-755-27088029

WhatsApp : +8615267039708